3 Hardware Configuration
However the serial port itself
1
has an option to control the signal DTR exactly as required for
RS 485 operation. This must be activated by configuration in the driver. Select Automatic DTR
as “RS 485 Low Active”, as seen in 4.2.3
Operation Mode Control DIP Configuration Driver Configuration
RS 232
RS 422
RS 485 4-wire by DTR Automatic DTR 4.2.3
RS 485 2-wire by DTR Automatic DTR 4.2.3
RS 485 2-wire with Echo by DTR Automatic DTR 4.2.3
Table 7: Modes on 200Ei PCIex
Also resistors for Termination and BIAS option are built-in, configured by other switches S3 and
S4 as of table 8.
DIP Function Remark
1 BIAS Tx+ Use with DIP 3
2 Termination Tx+ Tx 120
3 BIAS Tx Use with DIP 1
4 BIAS Rx+ Use with DIP 6
5 Termination Rx+ Rx 120
6 BIAS Rx Use with DIP 4
Table 8: Termination and BIAS on 200Ei PCIex
DIP are numbered top
down
3.2 VScom 200Ei-SI PCIex
In a functional view the 200Ei-SI is very similar to the non-isolated 200Ei, especially the config-
uration of operation modes and Termination/BIAS is the same. Configure the VScom 200EI-SI
PCIex exactly as the VScom 200EI PCIex card, as described above.